Dana McKenzie (European Spallation Source ERIC)
WEPS21
Coupler HV bias studies on ESS elliptical cavities
2743
We study the effects of high voltage DC bias on the fundamental power couplers of the ESS elliptical SRF cavities. These tests were carried out at the TS2 facility, where cryomodule acceptance and characterization tests are carried out. We present the observed effects of positive and negative bias field on multipacting in the RF couplers, as well as the implications for operation in the ESS linac.
Paper: WEPS21
DOI: reference for this paper: 10.18429/JACoW-IPAC2024-WEPS21
About: Received: 17 May 2024 — Revised: 18 May 2024 — Accepted: 18 May 2024 — Issue date: 01 Jul 2024